Skip to content

Welcome guest

Please login or register

Eisnova - User Manual

Eisnova User Manual

User Manual – Eisnova Recovery Chiller

1

Purpose

The Eisnova Recovery Chiller is designed to cool up to 300L of water to optimal cold plunge temperatures, maximizing cold therapy benefits.

2

Features

  • Temperature Control: Set desired temperature via touchscreen.
  • Built-In Thermometer: Displays real-time data.
  • Remote Control: Power and temperature adjustments from a distance.
  • Continuous Use: Operates 24/7, recommended restart every 7 days.
  • Compatibility: Works with any tub or ice bath.
  • Operating Temp: Efficient between 4°C and 40°C.
3

Operating Procedure

  • Place the unit on a flat surface near your tub.
  • Connect hoses with the external pump.
  • Pump draws warm water, chiller cools it, then recirculates back.
  • Automatic temperature regulation ensures consistency.
4

Quick Setup Guide

  1. Position chiller on a stable surface.
  2. Connect and secure hoses and fittings.
  3. Submerge pump, plug in and power on.
  4. Set temperature using the control panel.
5

Specifications

  • Cooling: Down to 5°C
  • Recommended Time: 2–4 hours to 9–11°C
  • Dimensions: 30.5 × 30.5 × 35.5 cm
  • Weight: 13.25 kg
  • Noise: 40–50 dB
  • Max Volume: 300L
6

Button & Menu Settings

Use SET and MODE buttons to adjust temperature and menu parameters.

  • P1 – Hysteresis (0–20°C)
  • P2 – Delay Start (1–20 min)
  • P3 – Calibration (-10°C to 20°C)
  • P4 – Always-On Function (0–10 min)
7

Precautions

  • Use indoors or in shaded dry areas.
  • Ensure 50cm clearance around unit.
  • Don’t cover or shake during operation.
  • Pre-rinse hoses before first use.
8

Troubleshooting

  • No display: Check power and switch.
  • No water flow: Ensure pump is submerged and working.
  • Slow cooling: Check environment, ensure proper ventilation.
9

Warranty

6-month limited warranty from delivery. If defective, replacement provided (customer covers return shipping). Refunds not issued due to environmental factors.

Frequently Asked Questions (FAQ)

  • Why not use ice? The chiller is cheaper and easier.
  • Best temp? 9–11°C for optimal performance and energy use.
  • Cooling time? 2–4 hours to 9–11°C.
  • Lowest temp? As low as 4°C.
  • 24/7 use? Yes, with auto on/off.
  • Safe? Yes, when used as directed.

Need help? Email us at support@eisnova.shop